High-voltage identification sleeving rated past the peak a traction loom sees under fault conditions.

Specification

Service temperature−70°C to +225°C (peaks to +300°C)
Impact resistanceLV 312-3 X < 25
IdentificationOrange, per ISO 17409 convention

Detail

Traction looms carry an identification requirement as well as a protection one. VH10 is supplied in the orange the convention expects, and it holds that colour through the full service range rather than browning off at the top of it.

The peak figure

+300°C is a peak, not a continuous rating, and it is listed separately for that reason. Continuous service is +225°C. Any supplier quoting a single number that happens to be the peak is quoting you a survival figure and calling it a specification.